Correct Answer:
Option C - As per IS 800-2007 Clause 10.2.3.3 –
• The gauge length 'g' should not be more than 100 +4t or 200 mm whichever is less in compression and tension member where t is the thickness of thinner outside plate.
• Minimum edge and end distance shall not be
(a) Less than 1.7 × hole diameter in case of sheared or hand flame out edges.
(b) Less than 1.5 × hole diameter in case of rolled, machine flame cut, sawn and planed edges.
C. As per IS 800-2007 Clause 10.2.3.3 –
• The gauge length 'g' should not be more than 100 +4t or 200 mm whichever is less in compression and tension member where t is the thickness of thinner outside plate.
• Minimum edge and end distance shall not be
(a) Less than 1.7 × hole diameter in case of sheared or hand flame out edges.
(b) Less than 1.5 × hole diameter in case of rolled, machine flame cut, sawn and planed edges.